The machine adopts an industrial-grade LCD display to display the current energy indicator, date, time, day, channel switch status and timing point networking information of each channel in real time, with delay on/off settings (0~120s) for each channel.
Each channel can be set with timing on/off time, multiple timing plans, and cycle timing switch. With a built-in high-precision clock chip, it can execute tasks based on the cycle time without manual operation, and can be connected to the network automatically for time calibration, making it easier for device management.
Equipped with a professional web page (computer, Android phone, iPhone, iPad) for login, management and control operation, enabling a stronger management function in system integration. With RS-232 serial control protocol, it supports external central control device control. With RS-485 serial port networking function, it can achieve sequential system installation for power-on from front to back and power-off from back to front.
Using universal (two-pin and three-pin plug, compatible with 10A and 16A) sockets, it can be compatible with the power interface of all products. A single unit features an 8-channel sequential power supply, with an optional filter (the model with E), a 2U chassis height, and an air switch device, beautiful in outlook, fine in workmanship.
With special undervoltage and overvoltage detection and alarm function, to provide reliable guarantee for your devices, with a maximum input current of 63A, a maximum output current of 16A for a single channel, and an operating voltage of 98V-240V.
Can achieve remote centralized control. Each device can be set to modify the code ID; each group name can be customized.
Can control the single on/off operation of the cascade power system by logging into the software (computer, mobile phone, iPad, etc.) after enabling the multi-machine cascade function.
Using terminal block wiring mode and 63A high-current air switch for device power input.
Equipped with various digital interfaces, including 1 male central control RS232, IN short-circuit trigger, short-circuit output 3.81MM green block, 1 set of 5V power supply auxiliary output 3.81MM green block, 1 set of RS485 3.81mm green block, 1 set of 12V trigger output 3.81mm green block, 2 USB power supply auxiliary ports (200mA max), and 1 RJ45 network port, supporting wireless WiFi router access, and also equipped with 2 national standard pass-through power output ports on the front panel.
Support software password login. The password can be changed for easy access to permissions.
The machine employs a professional industrial-grade power detection solution with specialized power calibration algorithms, providing more real-time parameters and minimizing errors, with voltage, current, power, and frequency clear at a glance.
Support multi-machine 485 long-distance cascade function, with a maximum capacity of 254 units.
Operating voltage: 110V~240V.
Output power sockets: 8 controlled universal sockets on the rear panel are compatible with various standards (universal sockets, EUR standard sockets, US standard sockets).
Socket standards: compatible with national standards of 6A, 10A and 16A.
On/Off interval time: Can be set freely.
Can display the current current, power, and voltage parameters in real time, enabling more convenient remote monitoring of the power system.
Can trigger the 8-channel power sequencing switches through the AC POWER TRIGGER.
Chassis height: 2U (88mm).
Model | D6578E |
Input/Output Voltage | AC100~240V |
Output Frequency | 50Hz |
Maximum Withstand Current | 63A |
Maximum Current for Single Channel | 16A |
Current Detection Accuracy | +/-0.1A |
Voltage Detection Accuracy | +/-1V |
Maximum Current for DC5V Output | 200mA |
Output Channel | 8 channels |
Set Time On/Off | 1-120s |
Timer | 8 channels |
Pass-Through Port | 2 channels |
RS232 | 1 channel |
RS485 | 1 channel |
IP | 1 channel |
WIFI | AP mode (Account: P2P0, Password: 12345678) |
Weight | 6kg |
Package Dimensions | 2U (550mm*300mm*150mm) |